Home » Fire Prevention » N2 Oxygen Reduction System
Prevent fires before they start
All traditional fire fighting technologies have the same problem in common. They are being used once the damage has occurred already. Whatever media is in use, foam, water mist, sprinklers, gas or water they are being activated after a fire has been detected. With the common and known methods fire is being fought only reactively. Often the damage caused by the extinguishing media is worse than the damage caused by the fire itself. Furthermore, there are many applications where the usage of water or gas would be fatal in its consequence. Applications like e.g. Data Centers, Server Rooms, Cold Stores, Paper Mills and many more. Whenever electricity comes into play the usage of water could end in a total disaster. Huge storages like cold store could not be flooded from a gas reservoir for example. ISOLCELL aims to provide the optimal solution for most of the above-mentioned applications to ensure absolute security by simply making the development of a fire impossible, replacing traditional fire fighting technologies.
“Completely eliminating the fire hazard and safeguarding people, buildings and it’s content is possible with ISOLCELL’s N2 ORS® oxygen depletion systems.”


This phase involves the generation of the oxygen-reduced atmosphere. All of Isolcell’s technologies for producing this atmosphere are green systems in the true sense of the word: they use only the air from the surrounding environment, without the addition of chemical substances or additives.
The atmosphere created is released into the area to be protected using a distribution network.
Using a special system called a ‘virtual grid’, a series of oxygen sensors analyse all of the protected area and relay the results to the control panel, so that the atmosphere is constantly analysed and monitored.
When an oxygen value other than the level desired is detected, the control panel activates the generators of the oxygen-reduced atmosphere for the period required to restore the defined values.
Thanks to the virtual grid and the rotation system, which is made possible because of the modularity of the generators, the system is able to optimise energy consumption and operating costs: in fact, the equipment alternates cyclically, thus limiting the hours of operation and reducing wear and maintenance.

When we talk about the air we breath we often and falsely talk about oxygen. In fact, the air we breath consists of 78,08 Vol.% of nitrogen and only 20,95 Vol.% of oxygen (0,93 Vol.% Argon and 0,04 Vol.% CO2). This ratio between nitrogen and oxygen is the same all over the world, high up in the mountains or low down at the sea. The food every fire needs to burn is the oxygen supplied by nature. By modifying the atmosphere and changing the ration between these two ingredients N2 Oxygen Reduction System® denies the fire enough “food” to get established.
The changed ratio has got the equivalent effect to human beings as a stay in high altitude or when travelling by plane as the lower air pressure drives the molecules apart and the amount of oxygen inhaled with every breath is less than in lower atmospheres.
Information relating access to the protected areas are illustrated: